Parameters, function | Values
|
Inverter input: |
|
Input voltage range | 9,5 - 16,1 (models 12/1300/70 and 12/2000/120) 19,0 - 32,2 (models 24/1300/70 and 24/2500/70)
|
Maximum input current | 200 A (model 12/1300/70) 400 A (model 12/2000/120) 150 A (model 24/1300/70) 300 A (model 24/2500/70)
|
Consumption capacity without load | 6 W (models 12/1300/70, 12/2000/120 and 24/2500/70) 8 W (model 24/1300/70)
|
Inverter output: |
|
Output voltage | 230 V AC ±1%
|
Frequency | 50/60Hz ±0,01% (crystal-controlled)
|
Nominal capacity | 1300 W (model 12/1300/70) 2000 W (model 12/2000/120) 1300 W (model 24/1300/70) 2500 W (model 24/2500/70)
|
Degree of efficiency during Ð nom. | 84% (model 12/1300/70) 85% (model 12/2000/120) 86% (model 24/1300/70) 87% (model 24/2500/70)
|
Protection | from overcharge, from short circuit
|
Battery charger input: |
|
Input voltage | 200-250 V AC
|
Maximum input current | 4,5 A (during 15 Â / 70 À) model 12/1300/70 7,7 A (during 15 Â / 120 À) model 12/2000/120 5,1 A (during 30 Â / 40 À) model 24/1300/70 8,7 A (during 30 Â / 70 À) model 24/2500/70
|
Degree of efficiency | 81% (during 15 Â / 70 À) model 12/1300/70 81% (during 15 Â / 120 À) model 12/2000/120 81% (during 30 Â / 40 À) model 24/1300/70 81% (during 30 Â / 70 À) model 24/2500/70
|
Ños / power factor | 1,0
|
Battery charger output: |
|
Current/voltage stability | ±1%
|
Output current range | 0 - 70 A, Uíîì = 12 Â (model 12/1300/70) 0 - 120 A, Uíîì = 12 Â (model 12/2000/120) 0 - 40 A Uíîì = 24 Â (model 24/1300/70) 0 - 70 A, Uíîì = 24 Â (model 24/2500/70)
|
Maximum voltage of pulses | Maximum 1,25
|
Switching: |
|
Maximum switching capacity | 3600 W
|
A time of switching to a net voltage to inverter | 20 mc
|
Switching capacity - inverter to a net | 187 V AC
|